UV 2100   UV 1601
 
UV Visible Double Beam Spectro Photometer
UV 1601 - Split Beam & Dual Detector (equivalent to Double beam Spectro Photometer )
 
Features
  • Wide wavelength range, satisfying requirements of various fields.
  • The split-beam ratio monitoring system provides accurate measurements and enhances baseline stability.
  • Five options for spectral bandwidth selection, 5nm, 5nm, 2nm, 1nm and 0.5nm, made according to customer’s need and satisfying the requirements of pharmacopoeia.
  • Fully automated design, realizing the simplest measurement.
  • Optimized optics and large scale integrated circuits design, light source and receiver from world famous manufacturer all add up to high performance and reliability.
  • Rich measurement methods, wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination, double-wavelength method and triple-wavelength method etc., meet different measurement requirements.
  • Automatic 10mm 8-cell holder, changeable to automatic 5mm – 50mm 4-posion cell holder for more choices.
  • Data output can be obtained via a printer port and a RS – 232 interface (RS 485 and USB port optional).
  • Parameters and data can be saved for user’s convenience.
  • PC controlled measurement can be achieved for more accurate and flexible requirement.
Specifications
Wavelength Range 190 -1100nm
Spectral Bandwidth 2nm (5nm,4nm,1nm,0.5nm optional)
Wavelength Accuracy ± 0.3nm
Wavelength Reproducibility 0.15nm
Photometric System Split-beam ratio monitoring ; Auto scan; Dual detectors
Photometric Accuracy ± 0.3 T (0-100%T), ± 0.002A (0-0.5A) ± 0.004A (0-5A- 1A)
Photometric Reproducibility 0.2%T
Working Mode T, A, C, E
Photometric Range -0.3-3A
Stray Light  ≤ 0.1% T (Nal , 220nm, Na NO2 340nm)
Baseline Flatness ± 0.002A
Stability 0.001A/30min (at 500nm, after warming up)
Noise ± 0.001A (at 500nm, after warning up)
Display 6 inches high light blue LCD
Detector Silicon photodiode
Power AC 220V/50Hz, 110V/60Hz, 180W
Dimensions 630 x 470 x 210mm
Weight 26kg
 
 
UV 2100
Features
  • Double beam, fully automated scanning system
  • Compatible PC controlled, rich analytical software.
  • Wavelength Scan :
  • Scanning sample spectra in any range within 190-900nm
  • Three scanning speed ; Fast, Middle and Slow selectable,
  • With Min. sampling interval of 0.04nm. Data processing function of derivative spectra and smoothing, peak picking, spectrum expansion and superposition and other arithmetic calculation.
  • Fixed wavelength measurement:  10 wavelength can be set at the same time.
  • Arithmetic calculation between wavelengths can be done.
  • Quantitation: standard factor method, standard contrast method : 2-wavelength method, and 3-wavelength method etc.
  • Kinetic measurement :  Wavelengths and sampling interval selectable, activity calculation available.
 
Specifications
Wavelength Range 190 - 900nm
Spectral Bandwidth 0.1, 0.2, 0.5, 1.0, 2.0nm
Wavelength Accuracy ± 0.3nm(0.15nm if required)
Wavelength Reproducibility 0.15nm
Photometric Accuracy ± 0.3% T (0-100%T), ±0.002A(0-0.5A), ± 0.0004A(0.5-1A)
Photometric Reproducibility 0.15%T
Working Mode T, A (-3-4A), C, E
Stray Light ≤ 0.05% T (Nal, at 220nm)
Baseline Flatness ± 0.001A
Stability 0.0004A/h (at 500nm, after warming up)
Detector  Photomultiplier
Light source Tungsten halogen lamp and deuterium lamp
Power AC 230V/50Hz, 110V/60Hz, 400W
Dimensions 670x470x210mm
Weight 45kg
 
UV 2601
Features
  • Wide wavelength range, satisfying requirements of various fields.
  • Five options for spectral bandwidth selection, 5nm, 4nm, 2nm, 1nm and 0.5nm, made according to customer’s need and satisfying the requirements of pharmacopoeia.
  • Fully automated design, realizing the simplest measurement.
  • Optimized optics and large scale integrated circuits design, light source and receiver from world famous manufacturer all add up to high performance and reliability.
  • Rich measurement methods, wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination, double-wavelength method and triple-wavelength method etc., meet different measurement requirements.
  • Automatic 10mm 8-cell holder, changeable to automatic 5mm-50mm 4-posion cell holder for more choices.
  • Data output can be obtained via a printer port and a RS – 232 interface ( RS 485 and USB port optional).
  • Parameters and data can be saved for user’s convenience.
  • PC controlled measurement can be achieved for more accurate and flexible requirement.
Specifications
Wavelength Range 190 – 1100nm
Spectral Bandwidth 2nm ( 5nm, 4nm,1nm,0.5nm optional)
Wavelength Accuracy ± 0.3nm
Wavelength Reproducibility ≤0.15nm
Optical System Double beam
Photometric Accuracy ± 0.3% T (0-100%T), ±0.002A(0-1A)
Photometric Reproducibility ≤0.15%T
Working Mode T, A, C, E
Photometric  Range -0.3-3.5A
Stray Light ≤ 0.1% T (Nal, 220nm, Na NO2 340nm)
Baseline Flatness ± 0.002A
Stability ≤0.001A/h (at 500nm, after warming up)
Noise ±0.001A (at 500nm, after warming up)
Display 6 inches high light blue LCD
Detector  Silicon photo-diode
Power AC 220 V/50Hz, 110V/60Hz, 180W
Dimensions 630x470x210mm
Weight 26kg
 
CT-2600/CT2800 Series Spectrophotometer
 
CT-2 Series are advanced double beam design consisting of four models; Stand-alone models: CT-2600 with 1.0 fixed bandwidth; and CT-2800 with 1.0nm bandwidth. The two detectors are measuring sample and reference respectively & simultaneously for optimizing measurement accuracy. It has application such as Biochemical research & Industry Pharmaceuticals analysis, Production, Education, Environment Protection, and Food Industry They provide accurate measurement in the range of 190nm to 1100nm.
 
All instruments provide excellent performance for measurements:
  • To Stand-alone models, all software methods are included as built-in standard, thus eliminating the need for software
    Options, UV Double Beam system has Large LCD Display and PC Interfacing facility together only
  • Data Download-to-PC software expands the data storage to unlimited.
  • Automatic 10mm 8-cell holder, changeable to automatic for 2800 & 10mm Single Cell Cuvettee holder for 2600
 
This spectrophotometer is suitable for pharmaceutical, biochemical and clinical lab applications as well as routine applications such as quantitative analyses, kinetics, spectrum scanning, multiple components and DNA/Protein analysis. PC Windows® application software and built-in software make this instrument versatile.
 
Specifications
 
A. Stand-alone models with large graphic LCD display (320 × 240) to directly show graphs on the screen.

B. Unique pre-aligned deuterium lamp for easy lamp replacement to avoid optical adjustment.
 
C. Powerful integrated software for data acquisition:
  • Quantitative
  • Basic Mode to measure the Absorbance and Transmittance
  • Kinetics available
  • Wavelength Scanning
  • Multi-Wavelength
  • DNA/Protein available
  • Concentration & DNA Purity are Quickly and easily calculated absorbance ratio 260/280nm with optional Subtracted absorbance at320nm DNA Concentration = 62.9 x A 260-36.0x A280 Protein Concentration= 1552x A260-757.3xA 280
 
D. Other features include:
  • Wide Wavelength range, satisfying, requirements of various fields, fully automated design, realizing the simplest measurement and satisfying the requirements of Pharmacopeia
  • Maximum of 9 Wavelength & 8 samples can be measured at one time, Automatic change-over between W Lamp & D2 Lamp
  • Optimized optics and large scale integrated circuits design & light source and receiver from world famous measurement method all add up to high performance and reliability
  • Rich measurements methods wave length scan, time scan, multi wavelength determination. Multi order derivative determination, double-wavelength method and triple –wavelength methods etc .meet difference measurement requirement,
  • Data output can be obtained via a printer port and a USB Interface.
  • Parameters and data can saved for user`s convenience
  • PC Controller measurement can be achieved for more accurate and flexible requirement
 

 

Model CT-2600 CT-2800
Optical System Double Beam, Grating 1200 lines/mm
Wavelength Range 190-1100nm
Spectral Bandwidth 1nm 1nm
Wavelength Accuracy ±0.3nm
Wavelength Repeatability 0.2nm
Photometric Accuracy ±0.3% T
Photometric Repeatability 0.15% T
Stray Light <0.05% T (220nm, 360nm)
Baseline Stability ±0.001 A/h @ (500nm)
Baseline Flatness ±0.001 A/h (200 - 1000nm)
Photometric Mode T, A, E
Scanning Speed High, Med., Low. , Max. 3600nm/min
Wavelength Setting Automatic
Photometric Range -0.3-3 A, 0-200% T, 0-9999 Conc.
Display Graphic LCD (320 * 240 Dots)
Detector Si Photodiode
Light Source Halogen & Deuterium Lamp (per-aligned)
Keyboard Membrane Keypad or PC
Output USB Port & Parallel Port (Printer)
Power Requirement AC 220V/50Hz or AC 110V/60Hz
Dimensions (W × D × H) 630mm × 470mm × 210mm 600mm × 450mm × 200mm
Weight 26Kg 27Kg
   
Packing List
Spectrophotometer (main system) 1
Mains Cord 1
Cuvettes Set of 4 glass, Set of 2 quartz
USB Cord: 1
User Manual
 
UV-Vis Analyst Software 1
Software Manual 1
Software Key 1
 
 
 
 
 
 
CT-8 Series Double Beam UV/Vis Spectrophotometer

CT-8 Series are advanced double beam design consisting of four models; Stand-alone models: CT-8200 with 1.8nm fixed bandwidth and CT-8600 with 1.0 fixed bandwidth; PC models: CT-8100 with 1.8nm fixed bandwidth and CT-8700 with 1.0nm fixed bandwidth. (Other specifications of the four styles are almost the same except bandwidth)
The two detectors are measuring sample and reference respectively and simultaneously for optimizing measurement accuracy. They provide accurate measurement in the range of 190nm to 1100nm.

All instruments provide excellent performance for measurements:

  • To Stand-alone models, all software methods are included as built-in standard, thus eliminating the need for software options.
  • On-line software upgrade capability via Internet helps to keep your software up-to-date.
  • Data Download-to-PC software expands the data storage to unlimited.

This spectrophotometer is suitable for pharmaceutical, biochemical and clinical lab applications as well as routine applications such as quantitative analyses, kinetics, spectrum scanning, multiple components and DNA/Protein analysis.
PC Windows® application software and built-in software make this instrument versatile.

 

Model

CT-8200

CT-8600

Optical System

Double Beam, Grating 1200 lines/mm

Wavelength Range

190-1100nm

190-1100nm

Spectral Bandwidth

1.8nm

1.0nm

Wavelength Accuracy

±0.3nm

Wavelength Repeatability

0.2nm

Photometric Accuracy

±0.2% T

Photometric Repeatability

0.15% T

Stray Light

<0.05% T

Baseline Stability

±0.0005 A/h

Baseline Flatness

±0.0005 A (200-1000nm)

Display

LCD (320 × 240) &
PC Model

LCD (320 × 240) &
PC Model

Photometric Mode

T, A, E

Scanning Speed

High, Med., Low. , Max. 3000nm/min

Wavelength Setting

Automatic

Photometric Range

-0.3-3 A, 0-200% T, 0-9999 Conc.

Detector

Si Photodiode

Light Source

Halogen & Deuterium Lamp (pre-aligned)

Keyboard

Membrane Keypad or PC

Output

USB Port & Parallel Port (Printer)

Power Requirement

AC 220V/50Hz or AC 110V/60Hz

Dimensions (W×D×H)

600mm × 450mm × 200mm

Weight

27 Kg

27Kg

 
 
 
 